We have elected to use PAPR’s for all tasks requiring respirator use. We also have an R95 nuisance respirator for those irritated by the odor who are not directly using the main product causing irritation, Peridox.
This has been effective so far.
Melissa Falcone, RN
Melissa Falcone, RN
| Manager
| Employee Health
PeaceHealth
| 2901 Squalicum Parkway
| Bellingham, WA 98225
office
360-788-6300 ext. 4571 |
mobile 360-383-8626
|
fax 360-715-4129
From: MCOH-EH [mailto:mcoh-eh-bounces@mylist.net]
On Behalf Of Grubbs, Scott
Sent: Monday, May 01, 2017 7:57 AM
To: MCOH/EH <mcoh-eh@mylist.net>
Subject: Re: [MCOH-EH] #ExtMail# Re: USP 800 Hazardous Drugs Medical Surveillance
This message originated outside of PeaceHealth's email system. VERIFY THE SENDER before opening attachments, clicking links or providing information.
The USP 800 text answers the question, it seems to me:
1
800 HAZARDOUS DRUGS—2
HANDLING IN HEALTHCARE SETTINGS
6.5 Respiratory Protection
543
For most activities requiring respiratory protection, an NIOSH-certified N95 or more
544
protective respirator is sufficient to protect against airborne particles; however, these
545
respirators offer no protection against gases and vapors and little protection against
546
direct liquid splashes (see CDC’s Respirator Trusted-Source Information at
547
http://www.cdc.gov/niosh/npptl/topics/respirators/disp_part/RespSource3healthcare.html
548
#e). Surgical masks do not provide respiratory protection from drug exposure and
549
should not be used to compound or administer drugs. A surgical N95 respirator provides
550
the respiratory protection of an N95 respirator and the splash protection provided by a
551
surgical mask.
552
Personnel unpacking HDs that are not contained in plastic should wear an elastomeric
553
half-mask with a multi-gas cartridge and P100-filter. If the type of drug can be better
554
defined, then a more targeted cartridge could be used.
555
Fit test the respirator and train workers to use respiratory protection. Follow all
556
requirements in the OSHA respiratory protection standard (29 CFR 1910.134)
557
(http://www.osha.gov/SLTC/etools/respiratory/index.html).
An appropriate full-facepiece,
558
chemical cartridge-type respirator shall be worn when attending to HD spills larger than
559
what can be contained with a spill kit, or when there is known or suspected airborne
560
exposure to powders or vapors.
Hope that helps.
Scott Grubbs, MD
WorkWell Occupational Health
Greenville, SC
From: MCOH-EH [mailto:mcoh-eh-bounces@mylist.net]
On Behalf Of Kumar, Bindu, MD
Sent: Tuesday, April 11, 2017 1:53 PM
To: MCOH/EH
Subject: #ExtMail# Re: [MCOH-EH] USP 800 Hazardous Drugs Medical Surveillance
No oddly I didn’t hear back from anyone.
From: MCOH-EH [mailto:mcoh-eh-bounces+kumarb=mlhs.org@mylist.net]
On Behalf Of Tara Dockery
Sent: Tuesday, April 11, 2017 1:51 PM
To: MCOH/EH
Subject: [EXTERNAL] [MCOH-EH] USP 800 Hazardous Drugs Medical Surveillance
HI Bindu – had asked this question a while ago. Did you receive any feedback on this? If so, would you mind forwarding it to me? Thank you!
Tara
Tara Lee Dockery, IP, MT(ASCP), BS
Infection Prevention and Employee Health
Ocean Beach Hospital and Clinics
174 First Avenue North
Ilwaco, Washington 98624
tdockery@oceanbeachhospital.com
Office Phone 360 – 642 - 6307
Cell Phone 509-760-7397
Fax 360-642-6309
From: MCOH-EH [mailto:mcoh-eh-bounces+tdockery=oceanbeachhospital.com@mylist.net]
On Behalf Of Bindu Kumar via MCOH-EH
Sent: Thursday, April 06, 2017 6:55 PM
To: MCOH/EH <mcoh-eh@mylist.net>
Cc: Bindu Kumar <bkumar00@yahoo.com>
Subject: Re: [MCOH-EH] USP 800 Hazardous Drugs Medical Surveillance
Anyone able to share their specific respirator requirements and fit testing plans under USP 800?
Thank you,
Bindu Kumar MD
Main Line Health
Sent from my iPhone
----------------------------
________________________________________________________________________________________________________
The information in this communication is intended to be confidential to the Individual(s) and/or Entity to whom it is addressed.
It may contain information of a Privileged and/or Confidential nature, which is subject to Federal and/or State privacy regulations.
In the event that you are not the intended recipient or the agent of the intended recipient, do not copy or use the information
contained within this communication, or allow it to be read, copied or utilized in any manner, by any other person(s). Should
this communication be received in error, please notify the sender immediately either by response e-mail or by phone,
and permanently delete the original e-mail, attachment(s), and any copies.
________________________________________________________________________________________________________
This message is intended solely for the use of the individual and entity to whom it is addressed, and may contain information that is privileged, confidential, and exempt from disclosure under applicable state and federal laws. If you are not the addressee, or are not authorized to receive for the intended addressee, you are hereby notified that you may not use, copy, distribute, or disclose to anyone this message or the information contained herein. If you have received this message in error, immediately advise the sender by reply email and destroy this message.