[MCOH-EH] Genome Equivalents as a measure of viral load

Swift, Melanie D., M.D., M.P.H. Swift.Melanie at mayo.edu
Tue Nov 12 08:26:07 PST 2019


Conversion differs slightly for each virus. I got this from something published (or presented, can't recall) by Mark Holodniy, MD, FACP, CIC, Professor of Medicine, Stanford University School of Medicine and Palo Alto VA. Viral load results may be expressed in copies/ml or genome equivalents (GE)/ml rather than international units (IU.) But, IU conversion factors are:
For HIV, 1 IU = 1.74 copies.
For HBV, 1 IU = 5.6 copies.
For HCV, 1 IU = 3.8 copies.

Following are recommended viral loads for infected HCW performing invasive procedures under SHEA guidelines compared to CDC:

SHEA recommendations:
Clinical Activities

Recommendation

Permissible Viral Load

"Category 1 or 2"
de minimis, or theoretical but unlikely risk

No practice restriction
Receive follow-up by personal physician
Adhere to optimal infection control procedures
Double glove for Category 2 procedures

N/A

"Category 3"
Definite Risk Procedure

Viral load check twice yearly
Restricted from high risk procedures if viral load above permissible level
Receive follow-up by personal physician
Adhere to optimal infection control procedures
Double glove for high risk procedures

HBV <10,000 GE/mL
(about 2000 IU/ml)
HCV <10,000 GE/mL
(about 2500 IU/ml)
HIV <500 GE/mL
(about 300 IU/ml)


CDC Recommendations (Hepatitis B only)
Clinical Activities

Recommendation

Permissible Viral Load

"Category 2" Low or No Risk Procedure

No panel oversight needed
Receive follow-up by personal physician

N/A

"Category 1" Definite Risk Procedure

Viral load check twice yearly
Restricted from high risk procedures if viral load above permissible level
Receive follow-up by personal physician
Adhere to optimal infection control procedures

HBV < 5,000 GE/mL (about 1,000 IU/ml)




Hope this helps,
Melanie

From: MCOH-EH [mailto:mcoh-eh-bounces at mylist.net] On Behalf Of Galaid Edward I
Sent: Tuesday, November 12, 2019 10:19 AM
To: mcoh-eh at mylist.net; Occ-Env-Med-L at listserv.unc.edu
Subject: [EXTERNAL] [MCOH-EH] Genome Equivalents as a measure of viral load

This is pertaining to the unit of measure that is used in the SHEA HCP with HBV/HCV/HIV infection document (https://www.shea-online.org/images/guidelines/BBPathogen_GL.pdf) to quantify viral load.

My Lab Director and his colleagues have not been able to come up with a conversion factor to express viral load as copies/mL or IU's.

Appreciate any info on how you're handling this.   This is not a new issue.  I am just stumped.

And maybe the SHEA document from 2010 is due for an update.

Thanks

Ed Galaid


Edward I. Galaid, MD, MPH, FACOEM
ABIM, ABPM (OM)
Medical Director, Roper St. Francis Physician Partners Occupational Medicine
Charleston, SC
Member, ACOEM Task Group,  Guidance for the Medical Evaluation of Law Enforcement Officers
(O) 843-402-5053



________________________________

Our Mission: Healing all people with compassion, faith and excellence.

Confidentiality Notice: This e-mail message, including
any attachments, is for the sole use of the intended
recipients and may contain confidential and/or legally
privileged information. If you are not the intended
recipient, please contact the sender by reply e-mail and
destroy all copies of the original message. Any
unauthorized review, use, disclosure, or distribution is
prohibited. Thank you.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <https://mylist.net/archives/mcoh-eh/attachments/20191112/527ad512/attachment.htm>


More information about the MCOH-EH mailing list