[MCOH-EH] OSHA-compliant portable audiometric testing machines?

Hinojosa, Camille Hinojosact at upmc.edu
Thu Jul 11 20:31:41 PDT 2019


We have a current audio program (Heartrak) and do audio testing in booth at our clinics and onsite in a trailer modified to limit ambient sound.  We were checking the sound level before testing but then one of our customers questioned if we were testing sound levels simultaneous.  We then asked for a bid from Shoebox but it was too expensive for us to recoup that cost.  We didn't find good alternatives on the vendor list from the last AOHC  meeting.  Sound level meters cost many thousands of dollars.  We haven't been charging for my professional review of audiograms but anyone seem to be losing money so might have to outsource the onsite testing?


I may be missing something

Camille T. Hinojosa, MD MPH C-MRO CPS/A

Medical Director of Occupational Health

The WorkCenter, UPMC Susquehanna

1100 Grampian Blvd.

Williamsport, PA 17701

p 570-320-7444

f 570-320-7445


This email may contain confidential information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this email and attached document(s) is prohibited. The information contained in this email and attached document(s) is intended only for the personal and confidential use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original email and attached document(s).




________________________________
From: MCOH-EH <mcoh-eh-bounces at mylist.net> on behalf of Cockrum, MD David S <dcockrum at frhs.org>
Sent: Monday, June 17, 2019 4:49 PM
To: MCOH/EH
Subject: Re: [MCOH-EH] OSHA-compliant portable audiometric testing machines?


Craig-



Because it’s a government agency, I don’t think OSHA “certifies” audiometric testing machines – that could be considered an “endorsement” which the government isn’t supposed to do. However, OSHA does very specifically outline the standards required for rooms in which audiometric testing should occur. These standards are defined here: https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95AppD

1910.95 App D - Audiometric test rooms | Occupational Safety and Health Administration - osha.gov<https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95AppD>
www.osha.gov
This Appendix is Mandatory. Rooms used for audiometric testing shall not have background sound pressure levels exceeding those in Table D-1 when measured by equipment conforming at least to the Type 2 requirements of American National Standard Specification for Sound Level Meters, S1.4-1971 (R1976), and to the Class II requirements of American National Standard Specification for Octave, Half ...




Most of the portable machines that I’ve seen attempt to compensate for the testing room ambient noise. Most commonly, the device includes what amounts to a dosimeter as part of the equipment. If the noise level exceeds any of the OSHA standards, the machine will stop the test until noise levels are back down. At least, that’s how I understand it.



Someone else mentioned ShoeBox Audiometry, which is one of the available portable testing systems. There are a couple of others, but I’m drawing a blank on their names. They had booths at the ACOEM meeting, which is always a good place to get leads on this kind of Occ Med related equipment.



David



DAVID
COCKRUM ,       MD
Physician
Faith Regional Physician Services
Occupational Health
[cid:image773329.png at 6C01EBCF.F6B9A400] (402) 844 8300<tel:(402)%20844%208300>
[cid:image492449.png at DBFEBE94.794EC3C7] 2024 Pasewalk Avenue, Suite 2   ,       Norfolk ,       NE              68701
[http://frhs.org/assets/images/logos/FRHScrosslogo_CMYKpng.png]<http://www.frhs.org/>
[http://frhs.org/assets/images/logos/FRPS-services-logo-color_CMYK.png]<http://www.frpsclinics.org/>
[http://frhs.org/assets/images/logos/stjoelogo_clr-SMALL.png]<http://frhs.org/about-us/locations-and-directions/affiliate-partners/st.-josephs-rehabilitation-care-center>
Click on the logos to learn more about our services.
This message and any attachments are confidential, may contain privileged or legally protected communications or information, and are intended solely for the recipient named above. If you are not the intended recipient, you are notified that any review, distribution, dissemination or copying of this message or any attachment is prohibited. If you have received this message in error, you should immediately notify the sender by a return e-mail and delete the message from your computer system.

From: MCOH-EH [mailto:mcoh-eh-bounces at mylist.net] On Behalf Of Thorne, Craig
Sent: Monday, June 17, 2019 10:13 AM
To: 'mcoh-eh at mylist.net' <mcoh-eh at mylist.net>
Subject: [MCOH-EH] OSHA-compliant portable audiometric testing machines?



This email originated from outside of the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. If you suspect the content of this email is malicious, please forward the email to abuse at frhs.org<mailto:abuse at frhs.org> .



Everyone, has there been any advancement with OSHA certifying “portable” audiometric testing machines (and not just the standard hearing booths)?



Any advice and references would be most appreciated!



Craig Thorne, M.D.



This message originates from the Yale New Haven Health System. The information contained in this message may be privileged and confidential. If you are the intended recipient you must maintain this message in a secure and confidential manner. If you are not the intended recipient, please notify the sender immediately and destroy this message. Thank you.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <https://mylist.net/archives/mcoh-eh/attachments/20190712/b479ab7f/attachment.htm>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: image773329.png
Type: image/png
Size: 443 bytes
Desc: image773329.png
URL: <https://mylist.net/archives/mcoh-eh/attachments/20190712/b479ab7f/attachment.png>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: image492449.png
Type: image/png
Size: 531 bytes
Desc: image492449.png
URL: <https://mylist.net/archives/mcoh-eh/attachments/20190712/b479ab7f/attachment-0001.png>


More information about the MCOH-EH mailing list